System Options
Geomet Versions - pre - 6.66.005.001
NOTE: Many of these options require access codes
supplied by Helmel Engineering. It is not recommended that changes be made here without
communicating with Helmel Technical Support. Changing some settings can adversely effect
the performance or accuracy of your CMM! |
Use Tool Tip Help
Default: Checked. When checked, activates the mouse tool tip help. When active, the
mouse can be held over a button, image or other control and after small period of rest, a
help display will appear to describe the control. NOTE: not all controls in Geomet
have tool tip help support.
Use Fast Access Menu
Default: Not Checked. The Fast Access Menu option in Geomet allows the user
to navigate stored programs through a fixed menu system. This allows single
button access to load and start a part program.
EZ Launch Menu System
Activates the EZ Launch Menu System. This menu system offers single touch
access to one or more assigned files when used manually. When used in
monitor mode, it receives inspection program instructions from a script file for automated
operations.
Enable DCC Motors
Available on DCC CMMs. When checked, this activates the auto drive systems. When
un-checked, the drives systems are disabled and complete manual inspections can take
place. The ability to activate this option is
controlled by the GeoSecure system and requires authorization from
Helmel Engineering.
Enable LDI Line Scanner
Available on DCC CMMs that have been built for the Laser Design Scanning
Probe. This option provides laser line scanning for
capturing data clouds over contour shapes. This option requires
authorization from Helmel Engineering.
Non-Linear Compensation
The use of non- linear compensation is set by the factory or
by the technician performing calibration on the CMM. This option involves the mapping of
your scales on the X, Y, and Z axes. See
Technical Note #2 for
enhanced description.
NOTE: Do not uncheck this option. Your
CMM calibration tables will be deactivated and the accuracy of your
CMM will be affected. The calibration tables are stored in a
separate file, "Lerror.dat" which is stored in your Windows folder.
If you inadvertently uncheck this option, just reset the check mark.
OptoDyne Laser Calibration
When activated this option will utilize the 3D volumetric calibration developed in
cooperation with
OptoDyne
Inc. This provides compensation not only to the linear characteristics of the CMM, but
also corrects for any squareness and parallelism of the CMM superstructure.
Skip Save Recover
Default: Un-Checked. During normal operations, Geomet maintains a recovery file. This
file is updated after the completion of any feature. This requires time and resources to
open the recovery file, write the file out to the hard drive, then close the file with
every feature. During long part runs or when operating on systems with limited
capabilities, this feature can be disabled saving time during part program runs.
Enable Fixture Reporting
Default: Not Checked. On the Header page of a part program, there exists three
edit controls where the operator can enter alpha numeric fixture data. Under most conditions, this is
not required. When checked, the 3 fixture edit controls will appear.
Enable Full DRO
Default: Not Checked. When checked, Geomet reconfigures the display to show
a large Digital ReadOut in area reserved for the normal graphics. This
provides a large readout of current the position which can be viewed from a
great distance such as moving around the CMM. When the full DRO is active,
the normal graphics display is disabled,
see Full DRO.
Enable Auto Sensing
Default: Not Checked. When checked Geomet reconfigures to sense for the current probe
direction vector, see
Auto-Direction for a complete description.
This option is only available on some CMM interfaces that allow time based monitoring of
CMM motion.
Enable IP Generation
Default: Not Checked. When checked, this activates a monitoring function that will
create a "memory" of your probe motions for each feature. This saved motion
becomes a motion map to the measured feature. This allows the teaching of the full motion
path in a part program on a manual CMM to be executed on a DCC CMM.
Full Prec. GDT Calculations
Default: Checked. When checked, Geomet performs calculations on tolerance data based on
full precision values eliminating rounding errors caused during reporting at a fixed
decimal place. For example, if the report decimal place is set at 3 places and the
reported values were transferred to manual calculations such as a spreadsheet, there can
exist a rounding error in excess of 0.00149 in the reporting of a 2D true position value.
Geomet, by default Geomet calculates at full decimal precision for greater accuracy of
results.
Applying your Selections
When finished making all your selections, press the
<Apply> button and close the System Options by pressing the <Ok> button.
return to System Options
|