Introduction
The Report Unit of Measurements cover:
- Inch / Metric
- Cartesian / Polar
- Degree.Decimal / Degree Minute Seconds
Can be controlled in-line with the building of the
inspection report, or on a feature-by-feature basis.
Command Activation
e Shift + E Ctrl + e |
Cartesian / Polar Inch / Metric Degree.Decimal / Degree Minute Seconds |
|
Keyboard |
Main Menu |
Toolbar |
The pressing of a corresponding key to change the
current Unit of Measurement acts as a toggle between the two choices
assigned to the key. Press the < e > key and it toggles between Cartesian and
Polar modes.
When changing states by pressing one of the
corresponding Unit of Measurement keys during the building of a inspection
program appends an action control record to the inspection report.
|
figure 1,
Status Banner |
The current state for all Unit of Measurement settings
can be identified quickly by referring to the Status Banner on the Geomet
Main Screen.
Changing Unit of Measurement of individual or a range
of existing features can easily be done using the
Feature
Properties Tool.
Related Procedures:
Feature Properties Tool,
System Options
|