Measuring with Multiple Styli
Search tool Information index
 
       
7.01.029 Geomet Junior+, 101, 101+, 301, 501 
      pre-version 7.01
  Definition
  During the inspection process, access to a feature is often limited to the feature's relationship to the current stylus. For example, if measuring a through bore that is parallel to the surface plate you will need either a long probe whose shaft is parallel to the bore and can reach the length of the bore, or the ability to use multiple styli where you can capture data points entering the bore from both ends.

Using a styli with a long shaft is not the preferred method due to the degradation in repeatable accuracy and just the fact that it is harder to capture data points inside a feature where visibility is often obscured.

By using multiple styli that are positioned to access much of the feature from different entry points, you can spread the data points over the entire feature assuring the highest possible confidence on the reported results.

The ideal condition is where you have an articulating probe, such as the Renishaw MH8 or PH10T. These probe heads provide repeatable positioning of the styli without the need to requalify.

The alternative method is the use of a star cluster that has up to 5 fixed styli attached to a common center. The star configuration can be positioned in the probe head mount to align the styli to the inspection fixture .
  Using Multiple Styli on Measured Feature
  In this example, we will measure a through bore that lies parallel to the surface plate and its axis is parallel to the X-Axis of the CMM. To setup the styli that will be needed, use the Stylus Manager to qualify the required positions. We will us two styli, one pointing in the -X direction, the other in the +X direction.
  Step 1
 
Activate the Stylus Manager and Activate the qualified styli that is orientated toward the -X direction.
Activating a Stylus
  Step 2
  Select the proper feature to be measured. Here we will use the cylinder with 16 points. Capture data points by entering the cylinder from the right side of the cylinder opening. Spread 8 data points around the full inside surface of the cylinder to a depth allowed by your sylus length. When these 8 data points have been captured, pull the stylus out of the cylinder an activate the Stylus Manager.

NOTE: If you are using a DCC style CMM, make sure you have included the necessary IPs between styli changes to provide safe movement during automatic inspections.
  Step 3
  The Geomet prompt will still show a cylinder is in progress and that there are 8 data points still required. When the Stylus Manager is opened during a feature measurement, you can choose a new stylus and set it active. Choose the stylus whose orientation is the +X direction and press the <+ Set Active> button. Geomet will not place a program statement in the report, but the Current Status banner will update to show the stylus change.

NOTE: You can use as many qualified styli as needed to measure a single position. The styli being chosen must be the same probe diameter.
  Step 4
  Capture the remaining 8 data points on the cylinder from the left opening. When all data points have been captured, Geomet will report the cylinder as a single feature.